Digital Substation

Digital Substation is an engineering publication focused on IEC 61850 automation, protection systems, and digital grid intelligence.

GOOSE (Technology)

Taxonomy feed.

IEC 61850 IOP 2026: What’s Happening on the Test Floor

IEC 61850 interoperability testing is under way in Utrecht, where equipment and software from multiple suppliers are being integrated into common protection, automation and control applications. Participant reports now cover functional protection tests, network configuration from SCD files and virtualised protection.

GOOSE is visible on the network, but the subscriber does not process it: a bug in the libIEC61850 library

The developers of the libIEC61850 library have released a fix for a bug that could cause valid GOOSE messages to be discarded by the receiving application. The problem affected version 1.6.2 and was caused by an incorrect Ethernet frame length check. The messages could be transmitted over the network successfully and appear in Wireshark, yet never reach the GOOSE subscriber's handler. This matters above all for developers of products supporting the IEC 61850 standard that use libIEC61850.

Inside DEWA's Digitally Optimized Substation Design

Conventional CTs hardwired to two multifunction IEDs per 132 kV bay from different manufacturers, GOOSE in place of interlock wiring, a virtualized SCMS, and a standard drawing set that ships with every tender. The design has now supported the construction of 90 substations in Dubai.

Wireshark Capture Filters for IEC 61850 Traffic: A Digital Substation Engineer's Cheatsheet

A practical reference for capture filters in Wireshark when working with IEC 61850 traffic. Why a display filter is not enough on a digital substation (especially of the process-bus generation), how a capture filter differs from a display filter, how the BPF (Berkeley Packet Filter) syntax is structured, and ready-to-use filter recipes for GOOSE and SV — from selecting by EtherType and OUI to APPID and multicast addresses.

confRev: How Configuration Revisions Can Ruin Communications

8 out of 10 configurators fail to fully recognize SCD files. We analyze the confRev attribute in GOOSE and SV: what happens when the value does not match the expected one, and how this nearly derailed the commissioning of a real project with 43 IEDs.

Top-Down IEC 61850 Engineering: The Five-Step Process, Explained

Top-down IEC 61850 engineering — formalized in TR IEC 61850-90-30:2025 and TR IEC 61850-7-6 (Ed. 2) — moves specification errors from commissioning to the design phase, before a single IED is selected or procured. This article explains the mechanics of the five-step process: what each step produces, what files are exchanged, and why the sequence achieves outcomes the conventional bottom-up approach cannot.

Explore Taxonomies