Digital Substation

Digital Substation is an engineering publication focused on IEC 61850 automation, protection systems, and digital grid intelligence.

SCL (Technology)

Taxonomy feed.

IEC 61850 IOP 2026: What’s Happening on the Test Floor

IEC 61850 interoperability testing is under way in Utrecht, where equipment and software from multiple suppliers are being integrated into common protection, automation and control applications. Participant reports now cover functional protection tests, network configuration from SCD files and virtualised protection.

CIM and IEC 61850 harmonization moves towards machine-readable models and rules

Work on harmonizing the Common Information Model (CIM) and IEC 61850 is increasingly focused on formal rules that software tools can process directly. For digital substations, this opens the way to automatic transformation of engineering data and automatic consistency checking between models at different levels.

Magical case #3: a documentation on IEC 61850 reporting — from an SCD or a set of CID files in one click

One run of Tekvel Magic software over SCL data — and you have a ready MS Word document - Signal list: a per-device summary, full detail of every URCB/BRCB control block and an element-by-element breakdown of every DataSet, with signal descriptions taken straight from the SCL. The module runs offline — from an SCD file or a folder of CID files, with no need to connect to the devices. The third case in the series closes the «how do you hand it over» task: handover documentation and as-built documentation in a single run, plus a separate «Configuration findings» document with a lightweight offline audit.

Magical Case Study #1: How to Verify That an SCD File Matches the Actual Device Configuration at a Digital Substation

A contractor hands over an SCD file claiming it matches the actual device configuration. But how do you verify that quickly and provably when there are 76 IEDs on site and no permanent monitoring system? A field case from Tekvel: the verification module in the Tekvel Magic software automatically compared the device configurations against the SCD and produced an engineering deviation report covering DataSets, GOOSE, Sampled Values and MMS reports in 15 minutes.

Top-Down IEC 61850 Engineering: The Five-Step Process, Explained

Top-down IEC 61850 engineering — formalized in TR IEC 61850-90-30:2025 and TR IEC 61850-7-6 (Ed. 2) — moves specification errors from commissioning to the design phase, before a single IED is selected or procured. This article explains the mechanics of the five-step process: what each step produces, what files are exchanged, and why the sequence achieves outcomes the conventional bottom-up approach cannot.

OCL in IEC 61850: Machine-Readable Rules for SCL Validation

If you have ever opened an SCL file from another vendor and wondered whether it is actually correct — not just well-formed XML, but semantically valid against the IEC 61850 standard — you already understand the problem that OCL is trying to solve.

Explore Taxonomies